ECU 000168.18 – ECU Supply Voltage Moderately Low. John Deere System Advisory.
ECU 000168.18 (ECU 168.18)
Code: 000168.18
Shortcode: 168.18
Description:
ECU 000168.18 flags a situation where the supply voltage (BAT) to the ECU is moderately low. This condition might be due to a weak battery, insufficient charging, or excessive electrical load on the system.
Reaction:
Moderate undervoltage can impair the functionality of the control software, potentially leading to limited vehicle operation or system malfunctions
Recommendations:
- Battery Inspection and Testing: Assess battery health and charge status to ensure it meets required specifications.
- Evaluate Charging System: Check the alternator and other charging system components for proper operation.
- Review Electrical Load: Identify and rectify any unnecessary electrical loads that may be drawing excessive power.
- Correct and Replace as Needed: Address issues with battery, wiring, or alternator to restore proper voltage levels.
- ECU System Check: After making necessary adjustments, check the ECU system to confirm full functionality has been regained.
Note:
Regular monitoring of the vehicle’s electrical system helps prevent issues related to inadequate voltage supply and ensures consistent performance.