ECU 000636.06 – Pump Position Sensor Circuit Low Resistance. John Deere System Advisory.
ECU 000636.06 (ECU 636.06)
Code: 000636.06
Shortcode: 636.06
Description:
Error code ECU 000636.06 is triggered when high current is detected in the wiring of the pump position sensor, indicating circuit resistance is too low, which typically suggests a short to ground. This abnormal condition can affect the accuracy of the pump position sensor’s readings, which are crucial for precise engine timing.
Reaction:
The ECU may adjust engine settings or display warning signals to prevent damage due to potential inaccuracies in pump positioning data.
Recommendations:
- Inspect Sensor Wiring: Check the wiring of the pump position sensor for any signs of damage, corrosion, or improper connections that could cause a short to ground.
- Measure Circuit Resistance: Utilize a multimeter to measure the resistance levels in the sensor circuit to confirm the low resistance diagnosis.
- Repair or Replace Wiring: Fix any identified issues with the wiring or connectors to restore proper circuit resistance.
- Reevaluate Sensor Operation: After repairs, test the pump position sensor to ensure it provides accurate readings to the ECU.
Note:
It is crucial to maintain correct wiring integrity to ensure reliable sensor performance and safeguard engine operations.