ECU 000647.06 – Proportional Solenoid Valve Current Too High (Charge Air Cooler Hydraulic Motor). John Deere System Advisory.
ECU 000647.06 (ECU 647.06)
Code: 000647.06
Shortcode: 647.06
Description:
Error code ECU 000647.06 is triggered when the ECU detects that the current at the proportional solenoid valve for the charge air cooler hydraulic motor is too high, indicating a grounded circuit. This affects the fan speed increase circuit.
Reaction:
The ECU may limit or disable the park lock function to prevent damage or malfunction due to the high current.
Recommendations:
- Inspect for Grounded Circuits: Check the wiring and connectors for the proportional solenoid valve for signs of grounding or short circuits.
- Measure Circuit Resistance: Use diagnostic tools to measure the resistance in the circuit and locate the short.
- Repair or Replace Damaged Components: Address any identified grounding issues by repairing or replacing faulty wiring or connectors.
- Test Solenoid Valve After Repair: Ensure the solenoid valve operates correctly after repairs, and the current is within the specified range.
- Reset ECU and Verify System: Reset the ECU and perform tests to ensure the solenoid valve functions correctly and no further errors are detected.
Note:
Proper electrical insulation and wiring maintenance are crucial to prevent short circuits and ensure reliable operation of the charge air cooler hydraulic motor.