ECU 003513.04 – Sensor Supply Voltage 5 Too Low. John Deere System Advisory.
ECU 003513.04 (ECU 3513.04)
Code: 003513.04
Shortcode: 3513.04
Description:
This diagnostic trouble code indicates that the fifth sensor supply voltage is below the expected 5-volt level, typically due to a short to ground. This under-voltage condition can lead to sensor malfunctions, affecting their ability to correctly monitor and report vehicle conditions.
Reaction:
The ECU may disable the affected sensors to prevent the propagation of inaccurate data and protect the system integrity, potentially leading to reduced functionality.
Recommendations:
- Inspect Circuit for Shorts: Look for any evidence of wiring or component faults that could cause the voltage to drop below normal levels.
- Measure and Document Voltage Output: Verify the voltage levels with a multimeter to diagnose the extent and location of the short.
- Resolve Grounding Issues: Address any identified issues by repairing or replacing the affected wiring or components.
- Reset ECU and Validate Sensor Outputs: After making the necessary repairs, reset the ECU to ensure that it correctly interprets sensor signals and conduct thorough tests to verify sensor functionality.
Note:
It is vital to ensure that all sensors receive stable and correct voltage supplies to maintain accurate monitoring and control systems within the vehicle. Regular checks and maintenance can prevent voltage issues and safeguard sensor operations.