EPC 000191.00 – Transmission Speed During Calibration Too High
EPC 000191.00 (EPC 191.00)
Code: 000191.00
Shortcode: 191.00
Description:
This error code, EPC 000191.00, indicates that the EPC has registered a transmission speed during the calibration of the transmission. This issue can be caused by:
- A defective transmission speed sensor (B104/B172).
- The tractor not being on a level surface during calibration, causing it to move (resulting in detected transmission speed).
Reaction:
When this error is detected, the calibration process may be interrupted or invalidated, preventing proper transmission calibration and potentially affecting overall performance.
Recommendations:
Inspect and Replace Transmission Speed Sensors:
- Check the condition and functionality of the transmission speed sensors (B104/B172). Replace them if they are found to be defective.
Ensure Stationary and Level Calibration Surface:
- Make sure the tractor is on a flat, level surface during the calibration process. Ensure that it remains stationary throughout the procedure to prevent movement.
Verify Sensor Connections:
- Inspect the wiring and connections to the transmission speed sensors for any signs of damage or loose connections. Repair or replace as necessary.
Recalibrate Transmission:
- After addressing the above issues, restart the transmission calibration process to ensure accurate calibration.
Note:
Proper calibration of the transmission is crucial for optimal performance. Regular maintenance and checks of sensors and calibration conditions can help prevent such errors.