ICC 523905.06 – Front PTO Driver Current Above Normal or Short to Ground
ICC 523905.06 (ICC )
Code: 523905.06
Shortcode:
Description:
This code indicates that the current for the front PTO driver is above normal, suggesting that the front PTO coil current is too high or there is a short to ground. This could be due to a short circuit in the wiring, a faulty coil, or issues within the control module.
Reaction:
The front PTO may not engage or operate correctly, and there could be a risk of blowing fuses or damaging other electrical components. The operator might see a warning light or message on the dashboard.
Recommendations:
- Inspect Front PTO Coil:
- Check the front PTO coil for proper operation and signs of short circuits.
- Replace the coil if necessary.
- Examine Wiring for Shorts:
- Inspect the wiring harness for signs of damage or shorts to ground.
- Repair or replace any damaged wiring.
- Test Control Module:
- Verify the functionality of the control module responsible for the front PTO.
- Replace the control module if necessary.
- Check for Grounding Issues:
- Ensure the front PTO circuit is not improperly grounded.
Note:
Routine checks and maintenance of the electrical system and PTO components can help prevent issues with the coil and ensure reliable operation.