PTA 524107.03 – Proportional Solenoid Valve 2 for Hydrostatic Unit, Voltage Too High
PTA 524107.03 (PTA )
Code: 524107.03
Shortcode:
Description:
This diagnostic trouble code is generated when the PTA control software registers a voltage value at the proportional solenoid valve 2 that does not correspond with the commanded working position of the hydrostatic unit. This indicates a general problem with the supply voltage (BAT) or that the circuit of proportional solenoid valve 2 is shorted to a positive lead.
Reaction:
Limited or no function of the transmission until the error is corrected, indicating a critical issue with the solenoid valve circuit.
Recommendations:
Inspect Solenoid Valve Circuit:
- Check the circuit for any short circuits to positive leads.
- Repair any identified issues in the circuit.
Test Proportional Solenoid Valve:
- Measure the voltage at the solenoid valve using a multimeter.
- Replace the solenoid valve if it is producing abnormally high voltage readings.
Examine Wiring and Connectors:
- Inspect all wiring and connectors associated with the solenoid valve for signs of damage or corrosion.
- Repair or replace any damaged components to ensure proper electrical connections.
Ensure Proper Power Supply:
- Verify that the solenoid valve is receiving the correct supply voltage.
- Correct any power supply issues that may be causing high voltage readings.
Note:
High voltage readings from the solenoid valve can lead to severe operational problems. Regular inspection and maintenance of the solenoid valve and its circuitry are essential to prevent these issues.