PTF 000158.04 – Control Software, Supply Voltage (ELX) Too Low
PTF 000158.04 (PTF 158.04)
Code: 000158.04
Shortcode: 158.04
Description:
This error code is triggered when the supply voltage (ELX) drops below 9 V. This undervoltage condition can result in the control software malfunctioning or not functioning at all.
Reaction:
When this code is detected, the control software may exhibit limited or no functionality.
Recommendations:
- Inspect Power Supply:
- Ensure the power supply is providing sufficient voltage.
- Check the voltage regulator for proper operation.
- Examine Wiring and Connections:
- Look for damaged wires, loose connections, or signs of corrosion.
- Repair or replace any defective components.
- Check Battery Health:
- Verify that the battery is in good condition and fully charged.
- Replace the battery if it is old or unable to hold a charge.
- Avoid Power Drains:
- Ensure there are no devices or components that are causing an excessive drain on the power supply.
Note: