PTI 524233.17 – Hydro Ring Unit (RU) Speed Low At Start-Up

PTI 524233.17 (PTI )

Code: 524233.17

Shortcode:

Description:

This error code is triggered when the hydro ring gear speed is incorrect at start-up. If PTI 523917.17 is also stored or active, then the input shaft from the engine is not running.

Reaction:

The control unit commands the equipment to enter Park mode, which is recoverable.

Recommendations:

  • Check Hydro Ring Gear Speed:
    • Verify that the hydro ring gear speed is within the expected range at start-up.
  • Inspect Input Shaft:
    • If PTI 523917.17 is present, check the input shaft from the engine to ensure it is running correctly.
  • Test Speed Sensors:
    • Ensure the speed sensors for the hydro ring gear are accurate and functioning correctly.
    • Replace any faulty sensors.
  • Evaluate Start-Up Procedures:
    • Verify that the start-up procedures are being followed correctly to ensure proper operation of the hydro ring unit.

Note:

Proper start-up procedures and accurate speed sensor readings are essential to prevent issues with the hydro ring unit and ensure smooth operation.


Control Units: John Deere

John Deere Parts