PTP 000158.01 – PTP Switched Supply Voltage Low
PTP 000158.01 (PTP 158.01)
Code: 000158.01
Shortcode: 158.01
Description:
This error code is triggered when the supply voltage to the PTP control unit drops below 9.0 V for longer than 2.0 seconds. Low supply voltage can impact the proper functioning of the control unit.
Reaction:
The control unit commands the transmission to neutral to prevent potential operational issues.
Recommendations:
- Inspect Electrical Connections:
Check all electrical connections to the PTP control unit for loose or corroded contacts. Secure and clean as necessary. - Battery Check:
Ensure that the battery is fully charged and in good condition. Replace the battery if it is weak or failing. - Alternator Output:
Verify that the alternator is providing adequate charging voltage to the system. Repair or replace the alternator if it is not functioning correctly. - Wiring Inspection:
Inspect the wiring harness for any damage or wear that could cause voltage drops. Repair or replace damaged wiring.
Note:
Maintaining stable supply voltage to the PTP control unit is vital for consistent and reliable operation. Regular checks of the electrical system can help prevent low voltage issues.