PTR 000158.01 – System Switched Voltage Low
PTR 000158.01 (PTR 158.01)
Code: 000158.01
Shortcode: 158.01
Description:
This error code, PTR 000158.01, is triggered by the Power Train Reverser (PTR) control unit when it detects that the system voltage drops below 9.0 V for more than 2 seconds. This can occur due to issues with the battery, alternator, or electrical connections causing insufficient power supply.
Reaction:
When this error is detected, the PTR control unit may limit the functionality of the transmission to prevent damage. The system may enter a protective mode, reducing performance or disabling certain features.
Recommendations:
Inspect Battery:
- Check the battery voltage and ensure it is fully charged.
- Test the battery for any signs of deterioration or failure. Replace if necessary.
Examine Alternator:
- Verify that the alternator is functioning correctly and providing adequate charging voltage.
- Inspect the alternator belt for wear and proper tension. Replace if worn or loose.
Check Electrical Connections:
- Inspect all electrical connections related to the PTR control unit, battery, and alternator.
- Ensure all connections are secure, clean, and free from corrosion.
Inspect Wiring:
- Check for any damaged or frayed wires in the electrical system.
- Repair or replace any faulty wiring to ensure proper voltage supply.
Monitor System Voltage:
- Use a multimeter to monitor the system voltage during operation.
- Ensure the voltage remains above 9.0 V under all operating conditions.
Update Software:
- Ensure that the PTR control unit software is up-to-date.
- Apply any available software updates or patches from the manufacturer.
Note:
Maintaining a stable system voltage is crucial for the proper operation of the PTR control unit. Regular maintenance of the electrical system can help prevent voltage-related issues. Ensure that all components are in good working condition to avoid disruptions.