RLC 002386.03 – Beacon Light, Voltage Too High
RLC 002386.03 (RLC 2386.03)
Code: 002386.03
Shortcode: 2386.03
Description:
This diagnostic trouble code is generated if a voltage higher than 16 volts is registered at the output to the beacon light. This indicates a short circuit to a positive lead.
Reaction:
When this error is detected, the control software may experience limited or no functionality of the beacon light.
Recommendations:
- Inspect Beacon Light Circuit:
- Check the wiring and connectors associated with the beacon light for signs of short circuits to a positive lead. Look for damaged insulation or exposed wires. Repair or replace any compromised wiring.
- Verify Voltage Regulation:
- Ensure the voltage regulator is functioning correctly and maintaining proper voltage levels. Replace the regulator if it is faulty.
- Test Beacon Light:
- Test the beacon light to ensure it is not damaged or causing the voltage increase. Replace any faulty light components.
- Check Power Supply:
- Ensure the power supply to the beacon light is stable and within the specified range. Inspect for any issues that could cause an overvoltage condition.
Note:
Excessive voltage can damage the beacon light and associated circuitry. Regular inspection and maintenance of the electrical system are essential to prevent such issues.