RLC 521559.05 – Right Side-Facing Worklight on Rear of Roof, Current Too Low
RLC 521559.05 (RLC )
Code: 521559.05
Shortcode:
Description:
This diagnostic trouble code is generated if the control software registers that the current at the output to the right side-facing worklight on the rear of the roof is too low. This indicates that the circuit is open.
Reaction:
When this error is detected, the control software may experience limited or no functionality of the worklight.
Recommendations:
- Inspect Worklight Circuit:
- Check the wiring and connectors associated with the right side-facing worklight for signs of open circuits. Look for disconnected or loose connections. Repair or replace any compromised wiring or connectors.
- Test Worklight:
- Test the right side-facing worklight to ensure it is functioning correctly and drawing the proper current. Replace any faulty light components.
- Verify Power Supply:
- Ensure the power supply to the worklight is stable and within the specified range. Inspect for any issues that could cause a drop in current.
Note:
An open circuit can prevent the worklight from functioning properly. Regular inspection and maintenance of the electrical system are essential to ensure reliable operation.