RPT 523811.05 – Solenoid for PTO Speed 1 On, No Current Present at PAP Control Software
RPT 523811.05 (RPT )
Code: 523811.05
Shortcode:
Description:
This diagnostic trouble code, RPT 523811.05, is generated when the PAP control software measures a current of less than 500 mA at the output to the solenoid for PTO speed 1 when the solenoid is turned on. This indicates that the circuit is open.
Reaction:
When this error is detected, the functionality of the rear PTO is significantly limited or entirely non-functional.
Recommendations:
Inspect Solenoid Circuit:
- Check the wiring and connections for the solenoid circuit for signs of an open circuit.
- Repair or replace any damaged wires or connectors.
Test Current Levels:
- Use diagnostic tools to measure the current levels at the solenoid for PTO speed 1.
- Ensure the current is within the specified range when the solenoid is activated.
Verify Solenoid Operation:
- Test the solenoid for proper operation and ensure it is receiving adequate current.
- Replace the solenoid if it is found to be faulty.
Update Control Software:
- Ensure that the PAP control software is updated to the latest version.
- Apply any available patches or updates that address current regulation issues.
Consult Technical Support:
- If the problem persists, consult with technical support or the equipment manufacturer for further assistance.
- Provide detailed error logs and current measurements to aid in troubleshooting.
Note: