RPT 523813.00 – Solenoid for PTO Speed 1, Current Overload Protection Active at PAP Control Software
RPT 523813.00 (RPT )
Code: 523813.00
Shortcode:
Description:
This diagnostic trouble code, RPT 523813.00, is generated when the PAP (Power Accessory Point) control software measures a total current above 40 A at the outputs to the solenoids for PTO speeds. This indicates a short to ground or a defective component in one of the monitored circuits.
Reaction:
When this error is detected, the functionality of the rear PTO is significantly limited or entirely non-functional.
Recommendations:
Inspect Solenoid Circuits:
- Check the wiring and connections for the solenoid circuits for signs of a short to ground.
- Repair or replace any damaged wires or connectors.
Test Solenoids:
- Use diagnostic tools to test the solenoids for proper operation and current draw.
- Replace any solenoids that are found to be defective.
Verify Current Levels:
- Measure the current levels at the outputs to the solenoids to ensure they are within the specified range.
- Address any issues related to excessive current draw.
Update Control Software:
- Ensure that the PAP control software is updated to the latest version.
- Apply any available patches or updates that address current overload protection issues.
Consult Technical Support:
- If the problem persists, consult with technical support or the equipment manufacturer for further assistance.
- Provide detailed error logs and current measurements to aid in troubleshooting.
Note:
Current overload protection is crucial for preventing damage to the PTO system and ensuring safe operation. Regular inspections and maintenance of the electrical components can help prevent such issues.