This diagnostic trouble code, RPT 523813.03, is generated when the PAP (Power Accessory Point) control software detects a voltage that is too high (12 volts) at the output to the solenoid for PTO speed 1 when the solenoid is turned on. This indicates a circuit that is open or shorted to 12 volts.
Reaction:
When this error is detected, the functionality of the rear PTO is significantly limited or entirely non-functional.
Recommendations:
Inspect Solenoid Circuit:
- Check the wiring and connections for the solenoid circuit for signs of an open circuit or a short to 12 volts.
- Repair or replace any damaged wires or connectors.
Test Voltage Levels:
- Use diagnostic tools to measure the voltage levels at the solenoid for PTO speed 1.
- Ensure the voltage is within the specified range when the solenoid is activated.
Verify Solenoid Operation:
- Test the solenoid for proper operation and ensure it is receiving the correct voltage.
- Replace the solenoid if it is found to be faulty.
Update Control Software:
- Ensure that the PAP control software is updated to the latest version.
- Apply any available patches or updates that address voltage regulation issues.
Consult Technical Support:
- If the problem persists, consult with technical support or the equipment manufacturer for further assistance.
- Provide detailed error logs and voltage measurements to aid in troubleshooting.
Note:
Proper voltage levels are essential for the correct operation of the solenoids and the PTO system. Regular inspections and maintenance of the electrical components can help prevent such issues.