SCC 524038.19 – SV IV External Control Fault Message Received
SCC 524038.19 (SCC )
Code: 524038.19
Shortcode:
Description:
This error code indicates that the external control data for Selective Control Valve IV (SV IV) has been received via CAN message with a failure indication. Fault messages can originate from the Resume Switch, iTEC™, Option Configuration Connector, or Attached Implements.
Reaction:
When this code is detected, the SCC functions will be degraded, impacting overall performance.
Recommendations:
Identify Fault Source:
- Determine which external control source (Resume Switch, iTEC™, Option Configuration Connector, or Attached Implements) is sending the fault message.
Inspect and Test External Control Source:
- Inspect the identified external control source for issues. Perform functional tests to verify its operation. Replace or repair the source if necessary.
Check Wiring and Connectors:
- Inspect all wiring and connectors associated with the identified external control source for signs of damage, poor connections, or corrosion. Repair or replace as necessary.
Monitor CAN Messages:
- Use diagnostic tools to monitor CAN messages from the identified external control source to SV IV, ensuring they are being received without faults.
Update Firmware and Software:
- Ensure all relevant components, including the SCC and identified external control source, have the latest firmware and software updates.
Consult Technical Support:
- If the issue persists, contact technical support for further diagnostics and assistance.
Note:
Fault messages from external control sources need prompt attention to prevent performance degradation and ensure system reliability.