SCC 524104.31 – SCV III Control Lever Command Missing

SCC 524104.31 (SCC )

Code: 524104.31

Shortcode:

Description:

This error code indicates that the SCV III (Selective Control Valve III) lever position data has not been received via CAN message. This can be due to communication issues, improper configuration, or a faulty lever.

Reaction:

When this code is detected, the SCC will disable the functions related to SCV III to prevent further issues.

Recommendations:

Verify Configuration:

  • Check the configuration of the SCV III control lever. Ensure it is correctly configured according to the manufacturer’s guidelines.

Inspect SCV III Control Lever:

  • Verify the functionality of the SCV III control lever. Replace the lever or sensor if it is found to be faulty.

Check Wiring and Connectors:

  • Inspect all wiring and connectors associated with the SCV III control lever for signs of damage, poor connections, or corrosion. Repair or replace as necessary.

Monitor CAN Messages:

  • Use diagnostic tools to monitor CAN messages from the SCV III control lever to the SCC, ensuring they are being received.

Update Firmware and Software:

  • Ensure all relevant components, including the SCC, have the latest firmware and software updates.

Consult Technical Support:

  • If the issue persists, contact technical support for further diagnostics and assistance.

Note:

Proper configuration and reliable communication are crucial for the accurate operation of SCV III.


Control Units: John Deere

John Deere Parts
John Deere Logo