SCO 520531.18 – Loader Bucket Position Sensor Value Too High
SCO 520531.18 (SCO )
Code: 520531.18
Shortcode:
Description:
This error code, SCO 520531.18, is generated when the control software receives a value for the loader bucket angle that is above the upper stop value of the return-to-position function. This indicates that the position sensor is reading values beyond the physical limits of the bucket.
Reaction:
When this fault is detected, the return-to-position function is not available.
Recommendations:
- Inspect Loader Bucket Mechanism:
- Check for any obstructions or mechanical issues that could cause the loader bucket to exceed its upper stop. Repair any mechanical faults.
- Verify Sensor Calibration:
- Ensure that the loader bucket position sensor is correctly calibrated. Recalibrate the sensor if necessary.
- Check Sensor Operation:
- Ensure that the loader bucket position sensor is functioning correctly. Replace the sensor if necessary.
- Consult Technical Support:
- If the issue persists, consult technical support for further diagnostics and assistance.
Note:
Regular Maintenance:
- Regularly inspect and maintain the loader bucket mechanism and position sensor to ensure proper operation and prevent faults.