UIC 001079.03 – 5Volt Components, Supply Voltage Too High

UIC 001079.03 (UIC 1079.03)

Code: 001079.03

Shortcode: 1079.03

Description:

This diagnostic trouble code (DTC) UIC 001079.03 is generated when more than 5.5 volts are measured at the positive power supply lead 6033 for 5-volt components (potentiometers for brake pedal, clutch pedal, speed control lever, accelerator pedal, and hand throttle) over a period of more than one second. This indicates a shorted circuit.

Reaction:

When this error occurs, the control unit may limit or disable the functionality of the affected components to prevent potential damage or unsafe operation.

Recommendations:

  • Inspect Power Supply Lead:
    • Check the positive power supply lead 6033 for any signs of damage, corrosion, or short circuits.
    • Ensure all connectors are securely attached and free from debris.
  • Check for Short Circuits:
    • Use diagnostic tools to detect any short circuits in the wiring connected to the 5-volt components.
    • Isolate and repair any identified short circuits.
  • Replace Faulty Components:
    • If specific components are found to be causing the overvoltage, replace them as necessary.
  • Consult Technical Support:
    • If the issue persists, contact John Deere technical support for further diagnostics and potential solutions.

Note:

Regular inspection and maintenance of the power supply leads and components can help prevent overvoltage issues.


Control Units: John Deere