UIC 523953.02 – Potentiometer of Speed Control Lever, Voltages at Channel 1 and Channel 2 Not in the Correct Ratio
UIC 523953.02 (UIC )
Code: 523953.02
Shortcode:
Description:
This diagnostic trouble code (DTC) UIC 523953.02 is triggered when the control unit detects a mismatch between the output signals of the potentiometer on the speed control lever (B67). The voltage at channel 1 (lead 6037) must be double the voltage of channel 2 (lead 6038).
Reaction:
When this error occurs, the control unit may limit the functionality of the speed control lever to ensure safe operation and prevent potential damage.
Recommendations:
- Inspect Potentiometer Connections:
- Check the wiring connections at the speed control lever potentiometer for any loose, damaged, or corroded connectors.
- Measure the output voltages at channel 1 (lead 6037) and channel 2 (lead 6038) to confirm the discrepancy.
- Verify Voltage Ratios:
- Ensure that the voltage at channel 1 is exactly double the voltage at channel 2. If the ratio is incorrect, recheck the wiring and sensor.
- Replace Potentiometer:
- If the wiring and connections are intact and the voltage ratio remains incorrect, consider replacing the potentiometer (B67).
- Consult Technical Support:
- If the issue persists, contact John Deere technical support for further assistance and potential software updates.
Note:
Intermittent faults in the wiring or connectors can cause voltage mismatches. Ensure a thorough inspection to avoid repeat occurrences.