UIC 523953.04 – Potentiometer of Speed Control Lever, Voltage at Channel 1 Too Low
UIC 523953.04 (UIC )
Code: 523953.04
Shortcode:
Description:
This diagnostic trouble code (DTC) UIC 523953.04 is generated when the control unit measures a voltage of less than 0.5 volts at the signal input from channel 1 of the potentiometer (B67, lead 6037). This indicates a problem at the signal lead or a problem with the potentiometer supply voltage.
Reaction:
When this error occurs, the control unit may limit the functionality of the speed control lever to ensure safe operation and prevent potential damage.
Recommendations:
- Inspect Signal Lead and Connections:
- Check the wiring connections at the speed control lever potentiometer for any loose, corroded, or damaged connectors.
- Measure the voltage at lead 6037 to confirm it is below 0.5 volts.
- Verify Potentiometer Supply Voltage:
- Ensure that the supply voltage to the potentiometer is within the specified range and is not causing the low voltage reading.
- Replace Potentiometer:
- If the wiring and connections are intact and the voltage remains too low, consider replacing the potentiometer (B67).
- Consult Technical Support:
- If the issue persists, contact John Deere technical support for further assistance and potential software updates.
Note:
Low voltage readings could also be due to intermittent faults in the wiring or connectors. Ensure a thorough inspection to avoid repeat occurrences.