UIC 524169.03 – B88 Sensor Unit for Brake Pedal (Potentiometer), Voltage Too High at Left Pedal
UIC 524169.03 (UIC )
Code: 524169.03
Shortcode:
Description:
This diagnostic trouble code (DTC) UIC 524169.03 is generated when the control unit measures a voltage in excess of 4.5 volts at the signal input of the left brake pedal potentiometer. This indicates a short in or a problem with the ground connection in the potentiometer’s circuit.
Reaction:
When this error occurs, the control unit may limit the functionality of the brake system to ensure safe operation and prevent potential damage.
Recommendations:
- Inspect Brake Pedal Sensor Unit:
- Check the B88 sensor unit for proper operation and ensure the left brake pedal potentiometer is not shorted or malfunctioning.
- Inspect Ground Connection:
- Ensure the ground connection for the potentiometer circuit is secure and free of corrosion or damage.
- Check Wiring and Connections:
- Inspect all wiring and connectors related to the left brake pedal potentiometer for any signs of shorts or damage.
- Replace Faulty Components:
- If the potentiometer or ground connection is found to be faulty, replace or repair as necessary.
- Consult Technical Support:
- If the issue persists, contact John Deere technical support for further diagnostics and potential solutions.
Note:
High voltage readings could also be due to intermittent faults in the wiring or connectors. Ensure a thorough inspection to avoid repeat occurrences.