UIC 524169.04 – B88 Sensor Unit for Brake Pedal (Potentiometer), Voltage Too Low at Left Pedal

UIC 524169.04 (UIC )

Code: 524169.04

Shortcode:

Description:

This diagnostic trouble code (DTC) UIC 524169.04 is generated when the control unit measures a voltage below 0.5 volts at the signal input of the left brake pedal potentiometer. This indicates a problem at the signal lead or a problem with the potentiometer supply voltage.

Reaction:

When this error occurs, the control unit may limit the functionality of the brake system to ensure safe operation and prevent potential damage.

Recommendations:

  • Inspect Brake Pedal Sensor Unit:
    • Check the B88 sensor unit for proper operation and ensure the left brake pedal potentiometer is functioning correctly.
  • Verify Potentiometer Supply Voltage:
    • Ensure that the supply voltage to the potentiometer is within the specified range and is not causing the low voltage reading.
  • Check Wiring and Connections:
    • Inspect all wiring and connectors related to the left brake pedal potentiometer for any signs of damage, corrosion, or loose connections.
  • Replace Faulty Components:
    • If the potentiometer or associated wiring is found to be faulty, replace or repair as necessary.
  • Consult Technical Support:
    • If the issue persists, contact John Deere technical support for further diagnostics and potential solutions.

Note:

Low voltage readings could also be due to intermittent faults in the wiring or connectors. Ensure a thorough inspection to avoid repeat occurrences.


Control Units: John Deere