UIC 524169.30 – B88 Sensor Unit for Brake Pedal (Potentiometer), Adjustment Error at Left Pedal
UIC 524169.30 (UIC )
Code: 524169.30
Shortcode:
Description:
This diagnostic trouble code (DTC) UIC 524169.30 is generated when the following conditions are present for more than 10 minutes:
- Voltage on the left potentiometer below 0.6 volts while the voltage on the right potentiometer is below 1.4 volts.
- Voltage on the left potentiometer above 1.4 volts while the voltage on the right potentiometer is below 1.4 volts.
- Voltage on the left potentiometer continuously above 1.3 volts (+/- 0.05 volts). This indicates the brake pedal is not adjusted correctly.
Reaction:
When this error occurs, the control unit may limit the functionality of the brake system to ensure safe operation and prevent potential damage.
Recommendations:
- Inspect Brake Pedal Sensor Unit:
- Check the B88 sensor unit for proper operation and ensure the left brake pedal potentiometer is functioning correctly.
- Adjust Brake Pedal:
- Ensure the brake pedal is correctly adjusted according to the manufacturer’s specifications to avoid continuous high or low voltage readings.
- Verify Potentiometer Signals:
- Confirm that the signals from both the left and right brake pedal potentiometers are within the expected range.
- Check Wiring and Connections:
- Inspect all wiring and connectors related to the brake pedal potentiometers for any signs of damage, corrosion, or loose connections.
- Replace Faulty Components:
- If the potentiometers or associated wiring are found to be faulty, replace or repair as necessary.
- Consult Technical Support:
- If the issue persists, contact John Deere technical support for further diagnostics and potential solutions.
Note:
Regular inspection and maintenance of the brake pedal sensor unit and its associated potentiometers can help prevent such faults and ensure reliable operation.