UIC 524173.03 – B65 Clutch Pedal Potentiometer, Voltage at Channel 1 Too High
UIC 524173.03 (UIC )
Code: 524173.03
Shortcode:
Description:
This diagnostic trouble code (DTC) UIC 524173.03 is generated when the control unit measures a voltage of more than 4.5 volts at the signal input from channel 1 of the potentiometer (B65, lead 6114). This indicates a problem at the signal lead or at the potentiometer ground connection.
Reaction:
When this error occurs, the control unit may limit the functionality of the clutch system to ensure safe operation and prevent potential damage.
Recommendations:
- Inspect Clutch Pedal Potentiometer:
- Check the B65 clutch pedal potentiometer for proper operation and ensure it is not shorted or malfunctioning.
- Inspect Ground Connection:
- Ensure the ground connection for the potentiometer circuit is secure and free of corrosion or damage.
- Check Wiring and Connections:
- Inspect all wiring and connectors related to channel 1 of the clutch pedal potentiometer for any signs of shorts or damage.
- Replace Faulty Components:
- If the potentiometer or ground connection is found to be faulty, replace or repair as necessary.
- Consult Technical Support:
- If the issue persists, contact John Deere technical support for further diagnostics and potential solutions.
Note:
High voltage readings could also be due to intermittent faults in the wiring or connectors. Ensure a thorough inspection to avoid repeat occurrences.