UIC 524173.03 – B65 Clutch Pedal Potentiometer, Voltage at Channel 1 Too High

UIC 524173.03 (UIC )

Code: 524173.03

Shortcode:

Description:

This diagnostic trouble code (DTC) UIC 524173.03 is generated when the control unit measures a voltage of more than 4.5 volts at the signal input from channel 1 of the potentiometer (B65, lead 6114). This indicates a problem at the signal lead or at the potentiometer ground connection.

Reaction:

When this error occurs, the control unit may limit the functionality of the clutch system to ensure safe operation and prevent potential damage.

Recommendations:

  • Inspect Clutch Pedal Potentiometer:
    • Check the B65 clutch pedal potentiometer for proper operation and ensure it is not shorted or malfunctioning.
  • Inspect Ground Connection:
    • Ensure the ground connection for the potentiometer circuit is secure and free of corrosion or damage.
  • Check Wiring and Connections:
    • Inspect all wiring and connectors related to channel 1 of the clutch pedal potentiometer for any signs of shorts or damage.
  • Replace Faulty Components:
    • If the potentiometer or ground connection is found to be faulty, replace or repair as necessary.
  • Consult Technical Support:
    • If the issue persists, contact John Deere technical support for further diagnostics and potential solutions.

Note:

High voltage readings could also be due to intermittent faults in the wiring or connectors. Ensure a thorough inspection to avoid repeat occurrences.


Control Units: John Deere