XSC 003511.03 – 5-Volt Supply Voltage 1 Too High

XSC 003511.03 (XSC 3511.03)

Code: 003511.03

Shortcode: 3511.03

Description:

This error code, XSC 003511.03, indicates that the voltage supply to the 5-volt components has exceeded 5.25 volts. This condition typically suggests a short to 12 volts, which can damage the 5-volt components and disrupt normal operation.

Reaction:

When this fault occurs, the control software will exhibit limited or no functionality, affecting the overall operation of the vehicle’s electronic systems.

Recommendations:

Inspect Electrical Connections:

  • Check the wiring and connectors associated with the 5-volt supply for any signs of damage, corrosion, or loose connections.
  • Ensure that there are no shorts to higher voltage lines (e.g., 12-volt lines).

Test Voltage Regulator:

  • Verify that the voltage regulator responsible for maintaining the 5-volt supply is functioning correctly.
  • Replace the voltage regulator if it is found to be faulty.

Monitor Voltage Levels:

  • Use diagnostic tools to monitor the voltage levels of the 5-volt supply in real-time.
  • Identify and correct any deviations from the normal operating range.

Consult Technical Support:

  • If the issue persists, contact John Deere technical support for further diagnostics and solutions.
  • Provide detailed logs of voltage readings and any steps already taken to address the fault.

Note:

Maintaining the correct voltage supply to electronic components is crucial for their reliable operation. Regular inspections and maintenance of the electrical system can help prevent such faults.


Control Units: John Deere