PTA 000161.02 – Sensor for Transmission Input Speed, Speed Drop Not Plausible

PTA 000161.02 (PTA 161.02)

Code: 000161.02

Shortcode: 161.02

Description:

This diagnostic trouble code is generated when the PTA control software detects that the transmission input speed has suddenly dropped to 0 rpm, which is not a plausible scenario under normal operating conditions.

Reaction:

Limited or no function of the transmission until the error is corrected, indicating a critical issue with the transmission input speed sensor or related circuitry.

Recommendations:

Inspect Input Speed Sensor:

  • Verify that the transmission input speed sensor is securely mounted and properly connected.
  • Replace the sensor if it is found to be defective.

Check Sensor Wiring:

  • Inspect the wiring harness for any signs of damage, wear, or disconnection.
  • Repair or replace any damaged wiring.

Verify Signal Integrity:

  • Use diagnostic tools to check the signal integrity from the input speed sensor.
  • Ensure the sensor is sending accurate and consistent data to the control unit.

Review Related DTCs:

  • Check for any additional diagnostic trouble codes that might be related and address them accordingly.

Note:

Sudden drops in transmission input speed readings can cause significant operational issues. Regular maintenance and prompt attention to sensor signals are crucial for reliable transmission performance.


Control Units: John Deere

John Deere Parts
John Deere Logo