PTA 000168.00 – Transmission Control Unit (AutoPowr/IVT), Supply Voltage (BAT) Too High
PTA 000168.00 (PTA 168.00)
Code: 000168.00
Shortcode: 168.00
Description:
This diagnostic trouble code is generated when the supply voltage (BAT) to the Transmission Control Unit (AutoPowr/IVT) exceeds 16 volts, indicating an overvoltage condition.
Reaction:
Limited or no function of the control software until the error is corrected, indicating a significant issue with the power supply.
Recommendations:
Inspect Power Supply:
- Check the battery and charging system for proper voltage regulation.
- Ensure the voltage does not exceed 16 volts.
Test Voltage Regulator:
- Verify that the voltage regulator is functioning correctly.
- Replace the voltage regulator if it is defective.
Examine Electrical Connections:
- Inspect all electrical connections related to the control unit for signs of damage or corrosion.
- Repair or replace any compromised connections.
Monitor Battery Condition:
- Ensure the battery is in good condition and properly charged.
- Replace the battery if it shows signs of overcharging or damage.
Note: