PTA 000168.01 – Transmission Control Unit (AutoPowr/IVT), Supply Voltage (BAT) Too Low

PTA 000168.01 (PTA 168.01)

Code: 000168.01

Shortcode: 168.01

Description:

This diagnostic trouble code is generated when the supply voltage (BAT) to the Transmission Control Unit (AutoPowr/IVT) falls below 9 volts, indicating an undervoltage condition.

Reaction:

Limited or no function of the control software until the error is corrected, indicating a serious issue with the power supply.

Recommendations:

Inspect Power Supply:

  • Check the battery and charging system to ensure they provide sufficient voltage.
  • Ensure the voltage does not drop below 9 volts.

Test Battery Health:

  • Verify the battery’s condition and charge level.
  • Replace the battery if it is weak or failing.

Examine Electrical Connections:

  • Inspect all electrical connections related to the control unit for signs of damage or corrosion.
  • Repair or replace any compromised connections.

Verify Alternator Function:

  • Ensure the alternator is charging the battery correctly.
  • Replace the alternator if it is not functioning properly.

Note:

Maintaining proper voltage levels is crucial for the reliable operation of the control unit. Regular checks on the battery and charging system can help prevent undervoltage issues.