PTA 000168.01 – Transmission Control Unit (AutoPowr/IVT), Supply Voltage (BAT) Too Low
PTA 000168.01 (PTA 168.01)
Code: 000168.01
Shortcode: 168.01
Description:
This diagnostic trouble code is generated when the supply voltage (BAT) to the Transmission Control Unit (AutoPowr/IVT) falls below 9 volts, indicating an undervoltage condition.
Reaction:
Limited or no function of the control software until the error is corrected, indicating a serious issue with the power supply.
Recommendations:
Inspect Power Supply:
- Check the battery and charging system to ensure they provide sufficient voltage.
- Ensure the voltage does not drop below 9 volts.
Test Battery Health:
- Verify the battery’s condition and charge level.
- Replace the battery if it is weak or failing.
Examine Electrical Connections:
- Inspect all electrical connections related to the control unit for signs of damage or corrosion.
- Repair or replace any compromised connections.
Verify Alternator Function:
- Ensure the alternator is charging the battery correctly.
- Replace the alternator if it is not functioning properly.
Note:
Maintaining proper voltage levels is crucial for the reliable operation of the control unit. Regular checks on the battery and charging system can help prevent undervoltage issues.