PTA 000177.03 – Sensor for Transmission Oil Temperature, Voltage Too High

PTA 000177.03 (PTA 177.03)

Code: 000177.03

Shortcode: 177.03

Description:

This diagnostic trouble code is generated when the PTA control software detects that the voltage at the signal input of the transmission oil temperature sensor is too high. This condition indicates that the sensor circuit is open or shorted to a positive lead.

Reaction:

Limited or no function of the transmission until the error is corrected, indicating a significant issue with the voltage levels in the sensor circuit.

Recommendations:

Inspect Sensor Circuit:

  • Check the sensor circuit for any open connections or short circuits to positive leads.
  • Repair any identified issues in the circuit.

Test Temperature Sensor:

  • Verify the sensor’s voltage output using a multimeter.
  • Replace the sensor if it is producing abnormally high voltage readings.

Examine Wiring and Connectors:

  • Inspect all wiring and connectors associated with the temperature sensor for signs of damage or corrosion.
  • Repair or replace as necessary to ensure proper electrical connections.

Ensure Proper Grounding:

  • Verify that the sensor and its circuitry are properly grounded.
  • Correct any grounding issues that may be causing voltage irregularities.

Note:

High voltage readings from the transmission oil temperature sensor can lead to severe operational problems. Regular inspection and maintenance of the sensor and its circuitry are essential to prevent these issues.


Control Units: John Deere