PTA 000191.08 – Transmission Output Speed Sensor, Speed at Channel 1 Lower Than at Channel 2
PTA 000191.08 (PTA 191.08)
Code: 000191.08
Shortcode: 191.08
Description:
This diagnostic trouble code is generated when the PTA control software detects a difference in frequency between the two sensor output signals for transmission output speed, indicating that the speed at channel 1 is lower than at channel 2.
Reaction:
Limited or no function of the transmission until the error is corrected, indicating a critical issue with speed synchronization.
Recommendations:
Verify Sensor Signals:
- Compare the output signals of both channels to ensure consistency.
- Replace the sensor if there is a discrepancy between the two channels.
Inspect Wiring and Connectors:
- Check the wiring and connectors of both channels for signs of damage or disconnection.
- Repair or replace any faulty components.
Ensure Proper Calibration:
- Verify that both channels are properly calibrated to provide accurate speed readings.
- Recalibrate if necessary.
Monitor Vehicle Operation:
- Ensure the vehicle is operating under normal conditions and not subject to irregular loads or speeds.
Note:
Accurate synchronization between the two sensor channels is essential for proper transmission operation. Regular monitoring and maintenance of sensors and their circuits can help prevent synchronization issues.