PTA 002005.09 – Incorrect CAN BUS Message, Information from TIA Control Software
PTA 002005.09 (PTA 2005.09)
Code: 002005.09
Shortcode: 2005.09
Description:
This diagnostic trouble code is generated when there is a data transfer problem between the PTA control software and the TIA control software. Intermittent or non-existent reception of messages sent on the CAN BUS by the TIA control software indicates an open circuit, a short circuit, or faulty CAN BUS terminating resistors.
Reaction:
Limited or no function of the control software until the error is corrected, indicating a critical communication issue.
Recommendations:
Inspect CAN BUS Wiring:
- Check the CAN BUS wiring for any signs of damage, wear, or disconnection.
- Repair or replace any damaged wiring.
Test CAN BUS Terminating Resistors:
- Verify the integrity and functionality of the CAN BUS terminating resistors.
- Replace any faulty resistors.
Ensure Proper Connections:
- Inspect all connectors associated with the CAN BUS for secure and proper connections.
- Clean or replace any corroded or loose connectors.
Verify TIA Software:
- Ensure the TIA control software is up to date and properly configured.
- Update the software if necessary.
Note: