PTA 522389.04 – Solenoid Valve for Clutch 4, Voltage Too Low
PTA 522389.04 (PTA )
Code: 522389.04
Shortcode:
Description:
This diagnostic trouble code is generated when the PTA control software detects a voltage value at the solenoid valve for clutch 4 that does not correspond with the switch status of clutch 4, indicating a short to ground or a defective solenoid valve.
Reaction:
Limited or no function of the transmission until the error is corrected, indicating a critical issue with the solenoid valve circuit.
Recommendations:
Inspect Solenoid Valve Circuit:
- Check the circuit for any short circuits to ground.
- Repair any identified issues in the circuit.
Test Solenoid Valve:
- Measure the voltage output to the solenoid valve using a multimeter.
- Replace the solenoid valve if it is producing abnormally low voltage readings.
Examine Wiring and Connectors:
- Inspect all wiring and connectors associated with the solenoid valve for clutch 4 for signs of damage or corrosion.
- Repair or replace any damaged components to ensure proper electrical connections.
Ensure Proper Grounding:
- Verify that the solenoid valve circuit is properly grounded.
- Correct any grounding issues that may be causing voltage irregularities.
Note: