PTA 522395.05 – Solenoid Valve for Clutch 2, Current Too Low
PTA 522395.05 (PTA )
Code: 522395.05
Shortcode:
Description:
This diagnostic trouble code is generated when the PTA control software registers a current value at the solenoid valve for clutch 2 that does not correspond with the switch status of clutch 2, indicating that the circuit of the solenoid valve for clutch 2 is open. The fault can be detected during power-up after ignition ON or when the transmission is in speed band 2.
Reaction:
Limited or no function of the transmission until the error is corrected, indicating a critical issue with the solenoid valve circuit.
Recommendations:
Inspect Solenoid Valve Circuit:
- Check the circuit for any open connections or breaks.
- Repair any identified issues in the circuit.
Test Solenoid Valve:
- Measure the current flow to the solenoid valve using a multimeter.
- Replace the solenoid valve if it is not drawing the correct current.
Examine Wiring and Connectors:
- Inspect all wiring and connectors associated with the solenoid valve for clutch 2 for signs of damage or disconnection.
- Repair or replace any damaged components to ensure proper electrical connections.
Ensure Proper Grounding:
- Verify that the solenoid valve circuit is properly grounded.
- Correct any grounding issues that may be causing low current flow.
Note: