SCO 522163.31 – INFORMATION FOR OPERATOR: Operator Presence Switch Not Activated While E-SCV XI is Activated

SCO 522163.31 (SCO )

Code: 522163.31

Shortcode:

Description:

This error code, SCO 522163.31, indicates that no signal has been received from the operator presence switch for more than 1 second while E-SCV XI is activated. The operator presence switch is crucial for ensuring the operator is in control when the selective control valve is in use.

Reaction:

When this fault is detected, the control software may limit or disable the function of the selective control valve (E-SCV XI).

Recommendations:

  • Check Operator Presence Switch:
    • Inspect the operator presence switch for any signs of damage or malfunction. Replace the switch if necessary.
  • Verify Wiring and Connections:
    • Ensure that the wiring and connections to the operator presence switch are secure and free from damage. Repair or replace any damaged components.
  • Test Switch Operation:
    • Test the operator presence switch to ensure it is functioning correctly and sending the appropriate signals.
  • Consult Technical Support:
    • If the issue persists, consult technical support for further diagnostics and assistance.

Note:

Safety Importance:

  • The operator presence switch is a critical safety feature. Regular inspection and maintenance of this switch are essential to ensure safe operation.

Control Units: John Deere

John Deere Parts
John Deere Logo