SCO 523804.19 – Multi-Function Lever (Potentiometer) Function 2, Fault
SCO 523804.19 (SCO )
Code: 523804.19
Shortcode:
Description:
This error code, SCO 523804.19, indicates that the value of the multi-function lever (function 2) cannot be determined and provided on the CAN Bus by the AIC control software. A transmitted replacement value generates this diagnostic trouble code. In its active state, this fault can also generate diagnostic trouble codes at the AIC control software, which take priority.
Reaction:
When this fault is detected, the selective control valve will not function.
Recommendations:
- Inspect CAN Bus Wiring:
- Check all CAN Bus wiring for signs of damage, loose connections, or corrosion. Secure and repair any issues found.
- Verify Multi-Function Lever (Function 2):
- Ensure that the multi-function lever (function 2) is functioning correctly. Recalibrate or replace the lever if necessary.
- Test CAN Bus Network:
- Test the CAN Bus network for proper communication and address any faults detected.
- Consult Technical Support:
- If the issue persists, consult technical support for further diagnostics and assistance.
Note:
Regular Monitoring:
- Regularly monitor the CAN Bus system to ensure reliable communication and proper functioning of the multi-function lever.