TCU 522379.03 – Y15/1 Park Lock Solenoid Valve 1, Voltage Too High

TCU 522379.03 (TCU )

Code: 522379.03

Shortcode:

Description:

This diagnostic trouble code (TCU 522379.03) is generated if the control unit detects a short to a positive lead at the signal input of park lock solenoid valve 1 (Y15/1, lead 6047). This indicates an electrical issue causing higher-than-expected voltage at the solenoid valve.

Reaction:

When this error code is detected, the equipment may experience issues with the park lock mechanism, leading to potential performance problems. The system might enter a protective mode to prevent further issues, resulting in limited operational capabilities.

Recommendations:

1. Inspect Solenoid Valve Circuit:

  • Check for Shorts: Inspect the wiring for any signs of shorting to a positive lead.
  • Ensure Secure Connections: Make sure all connections are secure and free of corrosion.

2. Test the Solenoid Valve:

  • Measure Voltage: Use a multimeter to measure the voltage at the signal input of the park lock solenoid valve.
  • Replace if Faulty: Replace the solenoid valve if it is providing high voltage readings.

3. Examine Wiring and Connectors:

  • Inspect for Damage: Check the wiring and connectors associated with the solenoid valve for damage or disconnection.
  • Repair or Replace: Repair or replace any damaged components.

4. Verify Control Unit Functionality:

  • Test Control Unit: Ensure that the control unit is correctly processing the solenoid valve signals.
  • Update Software: Update the control unit software if necessary.

Note:

Maintaining the solenoid valve and its associated circuitry is crucial for accurate park lock operation. Regular inspections and prompt repairs can help prevent issues related to high voltage readings.


Control Units: John Deere