TCU 524110.03 – B63 Sensor for Transmission Output Speed, Voltage at Channel 2 Too High

TCU 524110.03 (TCU )

Code: 524110.03

Shortcode:

Description:

This diagnostic trouble code (TCU 524110.03) is generated if the control unit detects that the voltage at the signal input from channel 2 of the transmission output speed sensor (B63, lead 6083) is too high. This indicates that there is a supply voltage problem or that the sensor’s circuit is open or shorted to a positive lead.

Reaction:

When this error code is detected, the equipment may experience issues with accurate transmission output speed readings, leading to potential performance problems. The system might enter a protective mode to prevent further issues, resulting in limited operational capabilities.

Recommendations:

1. Inspect Sensor Circuit:

  • Check for Shorts to Positive Lead: Inspect the wiring for any signs of shorting to a positive lead.
  • Ensure Secure Connections: Make sure all connections are secure and free of corrosion.

2. Test the Sensor:

  • Measure Voltage: Use a multimeter to measure the voltage at the signal input of channel 2 of the transmission output speed sensor.
  • Replace if Faulty: Replace the sensor if it is providing high voltage readings.

3. Examine Wiring and Connectors:

  • Inspect for Damage: Check the wiring and connectors associated with the sensor for damage or disconnection.
  • Repair or Replace: Repair or replace any damaged components.

4. Verify Control Unit Functionality:

  • Test Control Unit: Ensure that the control unit is correctly processing the sensor signals.
  • Update Software: Update the control unit software if necessary.

Note:

Maintaining the sensor and its associated circuitry is crucial for accurate transmission output speed readings. Regular inspections and prompt repairs can help prevent issues related to high voltage readings.


Control Units: John Deere

John Deere Parts
John Deere Logo