TIA 002003.09 – Incorrect CAN Bus Message, Information from PTA Control Software

TIA 002003.09 (TIA 2003.09)

Code: 002003.09

Shortcode: 2003.09

Description:

This diagnostic trouble code (DTC) is generated when there is a data transfer problem between the PTA control software and the TIA control software. The reception of messages sent on the CAN Bus by the control software is intermittent or non-existent, indicating a potential open circuit, short circuit, or faulty CAN Bus terminating resistors.

Reaction:

Limited or no function of the control software due to unreliable data communication.

Recommendations:

Inspect CAN Bus Wiring and Connections:

  • Check all CAN Bus wiring and connectors for any signs of damage, corrosion, or loose connections.
  • Repair or replace any faulty wiring or connectors.

Verify Terminating Resistors:

  • Ensure that the CAN Bus network is properly terminated with functioning resistors.
  • Replace any faulty or missing terminating resistors.

Check for Open or Short Circuits:

  • Use diagnostic tools to check for open circuits or short circuits in the CAN Bus lines.
  • Repair any identified circuit issues.

Update PTA and TIA Control Software:

  • Ensure that both the PTA and TIA control software are up-to-date with the latest versions provided by the manufacturer.

Consult Technical Support:

  • If the issue persists, consult technical support for further diagnostic procedures or potential hardware issues.

Note:

Regular inspection and maintenance of the CAN Bus network can prevent communication errors. Ensuring all components are functioning correctly is essential for reliable data transfer.


Control Units: John Deere