TIQ 002007.09 (TIQ 2007.09) – Incorrect CAN BUS Message, Information from RPT Control Software

TIQ 002007.09 (TIQ 2007.09)

Code: 002007.09

Shortcode: 2007.09

Description:

This error code is generated when there is a data transfer problem between the TIQ control software and the RPT control software. The reception of one, several, or all of the CAN messages transmitted by the RPT control software is intermittent or non-existent, potentially due to a loose wire or other communication issues.

Reaction:

When this fault is detected, the control software may exhibit limited or no functionality, affecting the overall operation of the equipment.

Recommendations:

  • Inspect CAN Bus Wiring and Connections:
    • Check for loose, damaged, or corroded wires and connectors between the TIQ and RPT control modules.
    • Repair or replace any faulty components.
  • Verify RPT and TIQ Communication:
    • Use diagnostic tools to monitor CAN Bus messages and ensure proper communication between the TIQ and RPT control software.
    • Address any identified communication gaps or errors.
  • Check for Interference:
    • Identify and eliminate sources of electrical interference that may disrupt CAN Bus communication.
    • Ensure proper grounding and shielding of CAN Bus cables.
  • Update Software:
    • Install any available updates or patches for the RPT and TIQ control software.
  • Consult Technical Support:
    • Contact technical support or the manufacturer for further assistance if the issue persists.

Note:

Maintaining secure and stable CAN Bus communication is essential for the reliable operation of control systems. Regular checks and updates can help prevent communication errors and ensure smooth performance.


Control Units: John Deere

John Deere Parts
John Deere Logo