TIQ 002071.09 (TIQ 2071.09) – Incorrect CAN BUS Message, Information from CCU Control Software

TIQ 002071.09 (TIQ 2071.09)

Code: 002071.09

Shortcode: 2071.09

Description:

This diagnostic trouble code is generated when there is a data transfer problem between the TIQ control software and the CCU control software. The issue may involve intermittent or non-existent reception of CAN messages transmitted by the CCU control software, potentially due to a loose wire or other communication issues.

Reaction:

When this fault is detected, the control software may exhibit limited or no functionality, affecting the overall operation of the equipment.

Recommendations:

  • Inspect CAN Bus Wiring and Connections:
    • Check for loose, damaged, or corroded wires and connectors between the TIQ and CCU control modules.
    • Repair or replace any faulty components.
  • Verify CCU and TIQ Communication:
    • Use diagnostic tools to monitor CAN Bus messages and ensure proper communication between the TIQ and CCU control software.
    • Address any identified communication gaps or errors.
  • Check for Interference:
    • Identify and eliminate sources of electrical interference that may disrupt CAN Bus communication.
    • Ensure proper grounding and shielding of CAN Bus cables.
  • Update Software:
    • Install any available updates or patches for the CCU and TIQ control software.
  • Consult Technical Support:
    • Contact technical support or the manufacturer for further assistance if the issue persists.

Note:

Maintaining secure and stable CAN Bus communication is essential for the reliable operation of control systems. Regular checks and updates can help prevent communication errors and ensure smooth performance.


Control Units: John Deere