TSC 001080.04 – 5volt Power Supply to Cab Suspension Sensor, Voltage Too Low

TSC 001080.04 (TSC 1080.04)

Code: 001080.04

Shortcode: 1080.04

Description:

This diagnostic trouble code, TSC 001080.04, is triggered when the voltage measured at the positive lead of the power supply to the 5-volt components (cab position sensor B110) is below 4.65 volts. This indicates a short to ground in the circuit.

Reaction:

When this error occurs, the affected sensor may not receive adequate power, leading to incorrect readings and impaired functionality of the cab suspension system.

Recommendations:

Inspect Power Supply Circuit:

  • Check for Shorts to Ground:
    • Examine the wiring for any signs of short circuits to ground.
    • Repair any identified shorts in the circuit.

Inspect Sensors:

  • Check Sensor Connections:
    • Ensure that the cab position sensor B110 is properly connected and not damaged.
    • Replace any faulty sensors.

Verify TSC Internal Circuitry:

  • Check for Internal Faults:
    • Inspect the internal circuitry of the TSC for any interruptions or faults.
    • Repair or replace the TSC if necessary.

Note:

Maintaining the stability of the 5-volt power supply to the cab suspension sensor is crucial for accurate sensor readings and proper system functionality. Regular inspections and maintenance of the power supply circuit and sensors are recommended.


Control Units: John Deere