TSC 523975.03 – TLS Axle All the Way Down, Voltage Too High (During Calibration)
TSC 523975.03 (TSC )
Code: 523975.03
Shortcode:
Description:
This diagnostic trouble code, TSC 523975.03, is triggered when, during calibration or bleeding, the TSC (TLS front-wheel drive axle) detects too high a voltage (more than 1.5 volts) at the signal output of the TLS position sensor (B53) when the TLS front-wheel drive axle is at its bottom position.
Reaction:
When this error occurs, the TLS system calibration process may fail, leading to incorrect positioning and operational issues.
Recommendations:
Inspect TLS Position Sensor:
- Check Sensor Output:
- Verify the signal output of the TLS position sensor B53 to ensure it is within the expected range when the TLS axle is at its bottom position.
- Recalibrate or replace the sensor if necessary.
Inspect Sensor Circuit:
- Check for Circuit Issues:
- Examine the wiring and connections of the TLS position sensor for any signs of damage, loose connections, or corrosion.
- Repair or replace any faulty components in the circuit.
Verify Calibration Process:
- Ensure Correct Calibration Procedure:
- Follow the manufacturer’s instructions for the calibration process.
- Ensure all necessary conditions (engine speed, tractor stationary) are met during calibration.
Note:
Proper calibration of the TLS front-wheel drive axle is essential for accurate positioning and smooth operation. Regular inspections and maintenance of the TLS position sensor and its circuit are necessary to prevent calibration faults.