TSC 523975.13 – TLS Axle in Level Position, Voltage Out of Range (During Calibration)
TSC 523975.13 (TSC )
Code: 523975.13
Shortcode:
Description:
This diagnostic trouble code, TSC 523975.13, is triggered when, at the end of calibration or bleeding, the TSC (TLS front-wheel drive axle) detects a level position voltage that is out of range (i.e., not between 2 and 3 volts) at the TLS position sensor (B53).
Reaction:
When this error occurs, the TLS system may not achieve the correct level position, potentially leading to operational issues and discomfort.
Recommendations:
Inspect TLS Position Sensor:
- Check Sensor Output:
- Verify that the signal output of the TLS position sensor B53 falls within the 2-3 volts range when the TLS axle is in the level position.
- Recalibrate or replace the sensor if necessary.
Inspect Sensor Circuit:
- Check for Circuit Issues:
- Examine the wiring and connections of the TLS position sensor for any signs of damage, loose connections, or corrosion.
- Repair or replace any faulty components in the circuit.
Verify Calibration Process:
- Ensure Correct Calibration Procedure:
- Follow the manufacturer’s instructions for the calibration process.
- Ensure all necessary conditions (engine speed, tractor stationary) are met during calibration.
Note: