UIC 000091.03 – Accelerator Pedal Potentiometer, Voltage at Channel 1 Too High
UIC 000091.03 (UIC 91.03)
Code: 000091.03
Shortcode: 91.03
Description:
This diagnostic trouble code (DTC) UIC 000091.03 is generated when the control unit measures a voltage of more than 4.5 volts at the signal input from channel 1 of the accelerator pedal potentiometer (B79, lead 6066). This indicates a problem either at the signal lead or at the potentiometer ground connection.
Reaction:
When this error occurs, the control unit may limit the engine performance to prevent unsafe operation, potentially resulting in reduced acceleration or a “limp mode” to ensure the vehicle remains controllable.
Recommendations:
- Inspect Signal Lead and Connections:
- Check the wiring connections at the accelerator pedal potentiometer for any loose, corroded, or damaged connectors.
- Measure the voltage at lead 6066 to confirm it exceeds 4.5 volts.
- Inspect Ground Connection:
- Ensure the ground connection of the potentiometer is secure and free of corrosion or damage.
- Replace Accelerator Pedal Potentiometer:
- If the wiring and connections are intact and the voltage is still too high, consider replacing the accelerator pedal potentiometer (B79).
- Consult Technical Support:
- If the issue persists after these checks, contact John Deere technical support for further assistance and potential software updates.
Note:
- High voltage readings could also be due to intermittent faults in the wiring or connectors. Ensure a thorough inspection to avoid repeat occurrences.
- Keeping a log of the error code occurrences and the conditions under which they happen can help in diagnosing intermittent issues.