VLC 522620.06 – Horn Circuit Current High
VLC 522620.06 (VLC )
Code: 522620.06
Shortcode:
Description:
This error code, VLC 522620.06, indicates that the Vehicle Load Center (VLC) control unit has detected that the current in the horn circuit exceeds the fuse rating of seven amps. This suggests a potential short circuit or excessive load in the circuit.
Reaction:
When this fault is detected, the horn will not operate, and the circuit’s fuse may blow to prevent damage, which can affect the vehicle’s ability to alert other drivers or pedestrians.
Recommendations:
Inspect Wiring and Connections:
- Examine the wiring and connectors in the horn circuit for any signs of short circuits, such as damaged insulation or exposed wires. Repair or replace any faulty wiring or connectors.
Check the Horn:
- Ensure that the horn is not drawing excessive current due to a fault. Replace any faulty horns.
Test the Relay and Fuse:
- Verify that the relay and fuse for the horn circuit are correctly rated and not faulty. Replace any blown fuses or malfunctioning relays with the correct ratings.
Measure Circuit Current:
- Use a multimeter to measure the current in the horn circuit to confirm it exceeds seven amps. Identify and rectify any sources of excessive current draw.
Consult Technical Support:
- If the problem persists, contact technical support for further diagnostics. Provide detailed information about the fault and the steps taken to resolve it.
Note:
High current in the horn circuit can be caused by factors such as short circuits, mechanical faults in the horn, or incorrect component ratings. Regular maintenance and careful inspection of the electrical system can help prevent such issues.