XSC 001504.14 – Operator Presence Switch, No-one on Operator’s Seat While AutoTrac is Running
XSC 001504.14 (XSC 1504.14)
Code: 001504.14
Shortcode: 1504.14
Description:
This error code, XSC 001504.14, indicates that no operator has been detected on the seat for more than 7 seconds while the AutoTrac function is activated. This safety feature is designed to prevent the vehicle from operating without an operator present.
Reaction:
When this fault occurs, the control software will exhibit limited or no functionality, particularly affecting the AutoTrac system. The system may halt operations to ensure safety.
Recommendations:
Inspect Operator Presence Switch:
- Check the operator presence switch for any signs of damage or wear.
- Ensure the switch is properly installed and functioning correctly.
Verify Operator Presence:
- Ensure the operator is seated correctly and the presence switch is engaged when operating the AutoTrac function.
Update Control Software:
- Check for and install any available updates for the control software to address potential bugs or signal processing issues related to the operator presence switch.
Consult Technical Support:
- If the issue persists, contact John Deere technical support for further diagnostics and solutions.
- Provide detailed logs of the operator presence switch readings and any steps already taken to address the fault.
Note:
Ensuring the operator presence switch functions correctly is essential for the safe operation of the AutoTrac system. Regular inspections and proper maintenance can help prevent such faults.