XSC 003512.04 – 5-Volt Supply Voltage 2 Too Low

XSC 003512.04 (XSC 3512.04)

Code: 003512.04

Shortcode: 3512.04

Description:

This error code, XSC 003512.04, indicates that the voltage supply to the 5-volt components has dropped below 4.75 volts. This condition suggests a short to ground or an internal fault within the control unit, which can disrupt normal operation and damage the components.

Reaction:

When this fault occurs, the control software will exhibit limited or no functionality, affecting the overall operation of the vehicle’s electronic systems.

Recommendations:

Inspect Electrical Connections:

  • Check the wiring and connectors associated with the 5-volt supply for any signs of damage, corrosion, or loose connections.
  • Ensure that there are no shorts to ground.

Test Voltage Regulator:

  • Verify that the voltage regulator responsible for maintaining the 5-volt supply is functioning correctly.
  • Replace the voltage regulator if it is found to be faulty.

Monitor Voltage Levels:

  • Use diagnostic tools to monitor the voltage levels of the 5-volt supply in real-time.
  • Identify and correct any deviations from the normal operating range.

Consult Technical Support:

  • If the issue persists, contact John Deere technical support for further diagnostics and solutions.
  • Provide detailed logs of voltage readings and any steps already taken to address the fault.

Note:

Maintaining the correct voltage supply to electronic components is crucial for their reliable operation. Regular inspections and maintenance of the electrical system can help prevent such faults.


Control Units: John Deere