XSC 522390.12 – Tractor-Implement Automation™, Fault

XSC 522390.12 (XSC )

Code: 522390.12

Shortcode:

Description:

This error code, XSC 522390.12, is generated when no valid information from the implement is received via the implement CAN Bus. This indicates a potential problem in the CAN Bus network or the implement control software, affecting the data communication necessary for Tractor-Implement Automation™.

Reaction:

When this fault occurs, the control software will deactivate all functions of the Tractor-Implement Automation™, affecting the overall automation capabilities of the tractor.

Recommendations:

Inspect CAN Bus Network:

  • Check the CAN Bus wiring and connectors for any signs of damage, loose connections, or corrosion.
  • Ensure all connections are secure and properly terminated.

Monitor CAN Bus Traffic:

  • Use diagnostic tools to monitor CAN Bus traffic and identify any anomalies or excessive errors.
  • Ensure that the CAN Bus network is not overloaded with unnecessary messages.

Verify Implement Control Software:

  • Ensure that the implement control software is up to date and functioning correctly.
  • Check for any software bugs or compatibility issues that may affect data transmission.

Consult Technical Support:

  • If the issue persists, contact John Deere technical support for further diagnostics and solutions.
  • Provide detailed logs of CAN Bus activity and any steps already taken to address the fault.

Note:

Maintaining a properly functioning CAN Bus network is crucial for effective communication and operation of the Tractor Implement Automation™. Regular inspections and maintenance of the CAN Bus components and control software can help prevent such faults.


Control Units: John Deere

John Deere Parts
John Deere Logo